Fire-Inspector-II 67 - Fire Inspector II Exam Questions and Answers

Questions 4

Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.

Options:

A.

12

B.

18

C.

24

D.

36

Buy Now
Questions 5

A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.

Options:

A.

hazardous materials

B.

flammable liquids only

C.

combustible liquids only

D.

corrosive materials only

Buy Now
Questions 6

Where requirements for fire safety are not specifically provided for by the International Fire Code, which of the following shall have the responsibility to determine the applicable requirements?

Options:

A.

City manager.

B.

Legal counsel.

C.

Board of appeals.

D.

Fire code official.

Buy Now
Questions 7

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not accessible to the public, is __ lb. water capacity.

Options:

A.

735

B.

1,000

C.

2,000

D.

2,500

Buy Now
Questions 8

The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.

Options:

A.

875

B.

1,000

C.

1,313

D.

1,750

Buy Now
Questions 9

An acceptance test for a fire alarm system in a new apartment building should be scheduled after:

Options:

A.

each zone is completed.

B.

the contractor verifies full compliance.

C.

the hydrostatic test of the underground main is completed.

D.

the system has been installed and operating for one year.

Buy Now
Questions 10

Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?

Options:

A.

Type I

B.

Type II

C.

Type III

D.

Type IV

Buy Now
Questions 11

Fine magnesium scrap stored in quantities greater than 1,000 cu. ft. shall be separated from all buildings other than those used for magnesium scrap recovery operations by a distance of not less than ___ ft.

Options:

A.

30

B.

50

C.

100

D.

250

Buy Now
Questions 12

Battery-charging areas for industrial trucks shall be protected with portable fire extinguishers which have a minimum rating of:

Options:

A.

4-A:20-B:C

B.

3-A:40-B:C

C.

2-A:10-B:C

D.

40-B:C

Buy Now
Questions 13

Exit signs shall have words on the sign in letters ___ inches in height.

Options:

A.

three

B.

four

C.

five

D.

six

Buy Now
Questions 14

A building occupied for aerosol storage shall be classified as which of the following occupancy classifications?

Options:

A.

High-hazard Group H

B.

High-hazard Group H-2

C.

High-hazard Group H-3

D.

Group S-1

Buy Now
Questions 15

Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?

Options:

A.

Group I-2

B.

Group A-1

C.

Office spaces

D.

Libraries in Group E

Buy Now
Questions 16

Clearance between tops of piles of combustible fibers and sprinkler heads shall not be less than ___ ft.

Options:

A.

2

B.

3

C.

4

D.

5

Buy Now
Questions 17

Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with

Options:

A.

UL 1975

B.

NFPA 11A

C.

CPSC 16CFR

D.

ASTM D 1784

Buy Now
Questions 18

Use, dispensing, and mixing of flammable liquids in open systems shall have continuous mechanical ventilation at a minimum rate of ___ CFM per sq. ft. of floor area.

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 19

A 501 gal. water capacity above-ground liquefied petroleum gas (LP-gas) tank located 20 ft. from a 250 gal. LP-gas tank must be separated a minimum of __ ft. from adjoining property.

Options:

A.

5

B.

10

C.

20

D.

25

Buy Now
Questions 20

Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.

How long must records related to this decision be maintained by the code official?

Options:

A.

Five years

B.

Three years

C.

Until the building is sold

D.

For as long as the building and the condition exist

Buy Now
Questions 21

Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.

Options:

A.

1/2-hour

B.

1-hour

C.

2-hour

D.

3-hour

Buy Now
Questions 22

The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:

Options:

A.

3,000 gpm for 3 hours.

B.

4,000 gpm for 4 hours.

C.

5,500 gpm for 4 hours.

D.

5,750 gpm for 4 hours.

Buy Now
Questions 23

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.

Options:

A.

735

B.

1,000

C.

2,000

D.

2,500

Buy Now
Questions 24

Given: A nonsprinklered building constructed with protected noncombustible material has a fire-resistive rating of a minimum of 1 hour. What is the most protective type of construction, from the choices below, that meets these parameters?

Options:

A.

IIA

B.

IIB

C.

IIIB

D.

VA

Buy Now
Questions 25

What fire-resistance rating is required for interior nonbearing walls and partitions in Type IV construction?

Options:

A.

0 hours

B.

1 hour

C.

1-1/2 hours

D.

2 hours

Buy Now
Questions 26

Given: In organic coating processes where Class I liquids are exposed to the air, Class I, Division I electrical installations are required to be outside the immediate vicinity of pumps or equipment.

"Immediate vicinity" means in addition to a vertical distance a zone extending from the vapor liberation point __ ft. horizontally in all directions.

Options:

A.

5

B.

10

C.

20

D.

50

Buy Now
Exam Code: Fire-Inspector-II
Exam Name: 67 - Fire Inspector II Exam